toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Engine Control Module > < Data Link Connector|Diagrams
Page 1
background image

EGR Vacuum Modulator: Testing and Inspection

INSPECTION 

1. Inspect exhaust gas recirculation vacuum modulator operation.

-

Disconnect the vacuum hoses from ports P, Q and R of the exhaust gas recirculation vacuum modulator.

-

Block ports P and R with your finger.

-

Blow air into port Q, and check that the air passes through to the air filter side freely.

-

Start the engine, and maintain speed at 2,500 rpm.

-

Repeat the above test. Check that there is a strong resistance to air flow.

-

If operation is not as specified, replace the exhaust gas recirculation vacuum modulator.

Engine Control Module > < Data Link Connector|Diagrams