Air Flow Meter/Sensor: Electrical Specifications

 

Resistance Measured Between Terminals THA - E2

10 - 20 K ohms at -4 deg F 

   

  

 

4 - 7 K ohms at 32 deg F 

    

 

  

 

2 - 3 K ohms at 68 deg F 

    

 

  

 

0.9 - 1.3 K ohms at 104 deg F 

    

 

  

 

0.4 - 0.7 K ohms at 140 deg F 

    

 

  

 

0.2 - 0.4 K ohms at 176 deg F 

    

 

  

 

 

Terminal Identification.