toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3053 > < Initial Inspection and Diagnostic Overview|Page 3051
Page 72
background image

(b) Disconnect the CAN No. 1 junction connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard resistance:

NG --  REPAIR OR REPLACE CAN BRANCH WIRE CONNECTED TO DLC3
OK -- Continue to next step.

2. CHECK FOR SHORT TO GND IN CAN BUS WIRE (CAN NO. 2 JUNCTION CONNECTOR)

(a) Turn the ignition switch off.

(b) Reconnect the CAN No. 1 junction connector.

(c) Disconnect the CAN No. 2 junction connector.

(d) Measure the resistance according to the value(s) in the table below.

Initial Inspection and Diagnostic Overview|Page 3053 > < Initial Inspection and Diagnostic Overview|Page 3051