toyota Workshop Repair Guides

Toyota Matrix XR 2WD L4-18L Workshop Service & Auto Repair Manual

Alternator|Removal and Installation|Page 4150 > < Alternator|Removal and Installation|Page 4148
Page 3
background image

a. Using an ohmmeter, check the continuity between terminals F and B

Standard:  When the positive and negative poles between terminals F and B are exchanged, there is continuity in one way but no continuity in
another way.

b. Using an ohmmeter, check the continuity between terminals F and E.

Standard:  When the positive and negative poles between terminals F and E are exchanged, there is continuity in one way but no continuity in
another way.

8. INSPECT GENERATOR REGULATOR ASSY

a. Using an ohmmeter, check that there is continuity between the slip rings.

Standard resistance: 2.1 - 2.5 ohm at 20°C (68°F)

b. Using an ohmmeter, check that there is no continuity between the slip ring and rotor.

Alternator|Removal and Installation|Page 4150 > < Alternator|Removal and Installation|Page 4148