toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Refrigerant|Capacity Specifications|Page 4940 > < Refrigerant|Capacity Specifications|Page 4938
Page 1
background image

Refrigerant: Testing and Inspection

REFRIGERANT 

ON-VEHICLE INSPECTION

1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

a. This is a method in witch the trouble is located by using a manifold gauge set. Read the manifold gauge pressure when the these conditions are

established.

Test conditions:
-

Temperature at the air inlet with the switch set at RECIRC is 30 - 35 °C (86 - 95 °F) Engine running at 1500 rpm

-

Blower speed control switch at "HI" position

-

Temperature control dial at "COOL" position

-

A/C switch ON

-

Fully open doors

1. Normally functioning refrigeration system.

Gauge reading:
Low pressure side:  0.15 -0.25 MPa (1.5 - 2.5 kgf/sq.cm)
High pressure side:  1.37-1.57 MPa (14 - 16 kgf/sq.cm)

2. Moisture present in refrigeration system.

Refrigerant|Capacity Specifications|Page 4940 > < Refrigerant|Capacity Specifications|Page 4938