A.C FAN NO.3 RELAY

2-5-2-3:

Closed with the Ignition SW ON, and A/C Magnetic Clutch Relay ON

H 7 HEATER RELAY

4-5:

Closed with the Ignition SW ON and Blower SW ON

A13 A/C THERMISTOR

1-2:

Approx. 1500 Ohms at 25° C (77° F)

A 3 A/C DUAL PRESSURE SW

1-4:

Open with the Refrigerant pressure at less than approx. 196.1 kPa (2.0 kgF/cm2, 28.4 psi) or more than approx. 3138.1 kPa (32.0
kgF/cm2, 458 psi)

A 3 A/C SINGLE PRESSURE SW

2-3:

Open with the Refrigerant pressure more than 1520 kPa (15.5 kgF/cm2, 220 psi)

W 4 WATER TEMP. SW (RADIATOR FAN)

1-GROUND: Open above approx. 90° C (194° F)

Closed below approx. 83° C (181° F)