toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Electrical Specifications|Page 3047 > < Electrical Specifications|Page 3045
Page 7
background image

Standard undercut depth: 
0.6 mm (0.024 in.) 
Minimum undercut depth
0.2 mm (0.008 in.) 
If the undercut depth is less than minimum, correct it with a hacksaw blade. 

Field Frame (Field Coil)
1. INSPECT FIELD COIL FOR OPEN CIRCUIT

Using an ohmmeter, check that there is continuity between the lead wire and field coil brush lead. If there is no continuity, replace the field frame.

2. INSPECT THAT FIELD COIL IS NOT GROUNDED

Using an ohmmeter, check that there is no continuity between the field coil end and field frame. If there is continuity, repair or replace the field
frame.

Brushes                                                                                                              

INSPECT BRUSH LENGTH

Using calipers, measure the brush length. 
Standard length: 
1.0 kw 13.5 mm (0.531 in.) 
1.4 kw 15.5 mm (0.610 in.) 
1.6 kw 15.5 mm (0.610 in.) 
Minimum length: 
1.0 kw  8.5 mm (0.335 in.) 
1.4 kw 10.0 mm (0.394 in.) 
1.6 kw 10.0 mm (0.394 in.) 
If the length is less than minimum, replace the brush holder and field frame.

Brush Springs

INSPECT BRUSH SPRING LOAD 

Electrical Specifications|Page 3047 > < Electrical Specifications|Page 3045