(c) Remove the bolt.

(d) Remove the bolt, clamp and clip, and disconnect the engine room main ware.

14. REMOVE INVERTER TERMINAL COVER

CAUTION:
Wear insulating gloves.

(a) Remove the 9 bolts and inverter terminal cover.

NOTICE:
Make sure to pull the inverter terminal cover straight up, as a connector is connected to the bottom of the cover.

15. CHECK TERMINAL VOLTAGE

CAUTION:
Wear insulating gloves.

NOTICE:
Do not allow any foreign objects or water to enter the inverter with converter assembly.

(a) Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

Standard voltage:

0 V

HINT
Use measuring range of DC 750 V or more on the voltmeter.

16. DISCONNECT FRAME WIRE

Components|Page 2521 > < Components|Page 2519