21. DISCONNECT WATER HOSE

(a) Release the retainer and disconnect the water hose from the inverter with converter assembly.

(b) Release the retainer and disconnect the water hose from the inverter with converter assembly.

(c) Disconnect the coolant hose from the inverter with converter assembly. Put a piece of cloth in the pipe and in the disconnected hose or cover

the pipe and hose with plastic bags as shown in the illustration, so that foreign matter doesn't stick to the union or the inside of the connector
and to prevent coolant from spilling near the inverter with converter assembly.

22. REMOVE INVERTER WITH CONVERTER ASSEMBLY

CAUTION:
Wear insulating gloves.

(a) Remove the 3 bolts and inverter with converter assembly.

NOTICE:
*

Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly.
When removing the inverter with converter assembly, do not damage the parts around it.

*

To prevent damage, do not hold the inverter with converter assembly by the connectors.

*

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

23. REMOVE MOTOR CABLE BRACKET

(a) Remove the 2 bolts and motor cable bracket.

Inverter With Converter|Page 2556 > < Inverter With Converter|Page 2554