NOTICE:
*

Since the inverter with converter assembly is very heavy, 2 people are needed to install the inverter with converter assembly.
When installing the inverter with converter assembly, do not damage the parts around it.

*

To prevent damage, do not hold the inverter with converter assembly by the connectors.

*

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

4. CONNECT WATER HOSE

(a) Connect the water hose to the inverter with converter assembly and lock the hose with the retainer.

NOTICE:
*

Insert the retainer until a click sound is heard.

*

Pull on the hose to confirm that the hose is securely connected.

*

If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.

(b) Connect the water hose to the inverter with converter assembly and lock the hose with the retainer.

NOTICE:
*

Insert the retainer until a click sound is heard.

*

Pull on the hose to confirm that the hose is securely connected.

*

If there is foreign matter on the union or the O-ring, clean it with water and finger scouring.

5. CONNECT NO. 2 ENGINE ROOM WIRE

(a) Disconnect the No. 2 engine room wire from the protector.

(b) Connect the No. 2 engine room wire with the bolt and 2 claws.

Torque : 8.3 Nm (85 kgf-cm, 73 in-lbf)

NOTICE:
Pass the No. 2 engine room wire under the two cooling hoses that pass beside the inverter.

(c) Install the No. 1 relay block cover and 2 clamps.

(d) Install the relay block cover.