toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Inverter With Converter|Page 2562 > < Inverter With Converter|Page 2560
Page 13
background image

NOTICE:
*

Make sure that the interlock is fully engaged.

*

Do not allow any foreign objects or water to enter the inverter with converter assembly.

(a) Temporarily install the frame wire (high voltage cables of the hybrid battery) and 4 bolts to the inverter assembly by hand.

(b) Fully tighten the 4 bolts.

Torque : 8.0 Nm (82 kgf-cm, 71 in-lbf)

NOTICE:
Be sure to use a torque wrench to tighten the bolts.

(c) Connect the harness clamp.

10. CHECK HIGH VOLTAGE CABLE CONNECTION

CAUTION:
Wear insulating gloves.

NOTICE:
Do not allow any foreign objects or water to enter the inverter with converter assembly.

(a) Check that each connector and terminal is firmly installed.

NOTICE:
Make sure that the bolts are fully tightened.

11. INSTALL INVERTER TERMINAL COVER

CAUTION:
Wear insulating gloves.

NOTICE:
*

Make sure that the interlock is fully engaged.

*

Do not allow any foreign objects or water to enter the inverter with converter assembly.

(a) Install the inverter terminal cover with the 9 bolts to the inverter with converter assembly.