(a) Connect the No. 2 water by-pass hose to the radiator reservoir.

HINT:  The direction of the hose clamp is indicated in the illustration.

10. INSTALL NO. 1 WATER BY-PASS PIPE

(a) Install the No. 1 water by-pass pipe to the upper radiator support with the 2 bolts.

Torque: 5.0 Nm (51 kgf-cm, 44 in-lbf)

11. INSTALL NO. 5 WATER BY-PASS HOSE

(a) Install the by-pass hose to the radiator and No. 1 water by-pass pipe.

HINT:  The direction of the hose clamp is indicated in the illustration.

12. INSTALL NO. 1 WATER BY-PASS HOSE

(a) Install the by-pass hose to the radiator reservoir and No. 1 water by-pass pipe.

HINT:  The direction of the hose clamp is indicated in the illustration.

13. CONNECT NO. 2 RADIATOR HOSE