toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Fuel Delivery and Air Induction > < Components|Page 3621
Page 1
background image

Positive Crankcase Ventilation Valve: Service and Repair
Installation

2AR-FE EMISSION CONTROL: PCV VALVE: INSTALLATION

INSTALLATION

1. INSTALL VENTILATION VALVE SUB-ASSEMBLY

(a) Apply adhesive to 2 or 3 threads of the ventilation valve.

Adhesive:
Toyota genuine adhesive 1324, three bond 1324 or equivalent

(b) Using a 19 mm deep socket wrench, install the ventilation valve.

Torque: 27 Nm (275 kgf-cm, 20 ft-lbf)

(c) Connect the No. 2 ventilation hose to the ventilation valve.

2. INSTALL INTAKE MANIFOLD

(a) Install the intake manifold See: Engine, Cooling and Exhaust/Engine/Intake Manifold/Service and Repair/Installation.

3. INSPECT FOR OIL LEAK See: Engine, Cooling and Exhaust/Engine/Engine Lubrication/Engine Oil/Service and Repair/Replacement

Fuel Delivery and Air Induction > < Components|Page 3621