toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Component Inspection|Page 2320 > < Component Inspection|Page 2318
Page 1
background image

Variable Valve Timing Actuator: Service and Repair

REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:  Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.

2. REMOVE ENGINE ASSEMBLY

a. Remove the engine.

3. REMOVE INTAKE AIR SURGE TANK ASSEMBLY.

4. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY

a. Disconnect the 4 oil control valve connectors.
b. Remove the 4 bolts and 4 oil control valves.
c. Remove the O-ring from each oil control valve.

INSTALLATION

1. INSTALL CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY

a. Apply a light coat of engine oil to new 4 O-rings of the oil control valves.
b. Install the O-rings to the 4 oil control valves.

Component Inspection|Page 2320 > < Component Inspection|Page 2318