toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Condenser HVAC|Diagrams|Page 7673 > < Condenser HVAC|Diagrams|Page 7671
Page 1
background image

Condenser HVAC: Service and Repair

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:  Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.

3. REMOVE FRONT BUMPER COVER

a. Remove front bumper cover.

4. DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE

a. Remove the bolt and disconnect the cooler refrigerant discharge hose from the cooler condenser.
b. Remove the O-ring from the cooler refrigerant discharge hose.

NOTE: Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.

5. DISCONNECT COOLER REFRIGERANT LIQUID PIPE

a. Remove the bolt and disconnect the cooler refrigerant liquid pipe from the cooler condenser.
b. Remove the O-ring from the cooler refrigerant liquid pipe.

NOTE:  Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.

6. REMOVE RADIATOR SUPPORT UPPER BRACKET

a. Remove the 2 bolts and 2 brackets.

Condenser HVAC|Diagrams|Page 7673 > < Condenser HVAC|Diagrams|Page 7671