RAV4 2WD V6-3.5L (2GR-FE) (2006)
Main Relay (Computer/Fuel System): Testing and Inspection
ON-VEHICLE INSPECTION
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.
2. INSPECT INSTRUMENT PANEL JUNCTION BLOCK
NOTE:The circuit opening (C/OPN) relay is built into the instrument panel junction block.
a. Measure the resistance between the terminals.
If the result is not as specified, replace the instrument panel junction block.
3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL