toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Hose/Line HVAC|Specifications|Page 1242 > < Hose/Line HVAC|Specifications|Page 1240
Page 1
background image

Hose/Line HVAC: Service and Repair

 Refrigerant Lines

REFRIGERANT LINES REPLACEMENT

1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM

2. REPLACE FAULTY TUBE OR HOSE

NOTE:  Cap the open fittings immediately to keep moisture or dirt out of the system.

3. TORQUE CONNECTIONS TO SPECIFIED TORQUE

NOTE:  Connections should not be torqued tighter than the specified torqued.

Receiver x Liquid tube

Torque: 6.0 N.m (60 kg.cm, 52 in.lb)

Condenser x Discharge tube

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Condenser x Liquid tube

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Compressor x Discharge tube

Torque: 10 N.m (100 kg.cm, 7 ft.lb)

Cooling unit x Liquid tube

Torque: 14 N.m (140 kg.cm, 10 ft.lb)

Cooling unit x Suction tube

Torque: 32 N.m (330 kg.cm, 24 ft.lb)

Expansion valve x Evaporator

Torque: 5.4 N.m (55 kg.cm, 48 in.lb)

Suction lines

Torque: 32 N.m (330 kg.cm, 24 ft.lb)

Liquid lines

Torque: 14 N.m (140 kg.cm, 10 ft.lb)

4. EVACUATE AIR IN REFRIGERATION SYSTEM AND CHARGE WITH REFRIGERANT

Specified amount:

700 ± 50 g (24.69 ± 1.76 oz.)

Hose/Line HVAC|Specifications|Page 1242 > < Hose/Line HVAC|Specifications|Page 1240