Canister Purge Control Valve: Service and Repair
Removal

2AR-FE EMISSION CONTROL: PURGE VALVE: REMOVAL

REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:  Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

2. REMOVE PURGE VSV

(a) Disconnect the purge VSV connector.
(b) Disconnect the wire harness clamp.
(c) Disconnect the 2 purge line hoses from the purge VSV.
(d) Remove the purge VSV from the air cleaner hose.