toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

ABS/TCS - Zero Point Calibration Information|Page 6182 > < ABS/TCS - Zero Point Calibration Information|Page 6180
Page 3
background image

3. Turn the ignition switch OFF.

4. CLEAR ZERO POINT CALIBRATION DATA (When not Using Intelligent Tester)

a. Clear the zero point calibration data. 

1. Turn the ignition switch ON.
2. The warning light and indicator light come on for 3 seconds to indicate that the initial check is completed.

3. Using SST, connect and disconnect terminals 12 (TS) and 4 (CG) of the DLC3 4 times or more within 8 seconds.

SST 09843-18040

4. Check that the VSC warning light comes on.
5. Remove SST from the terminals of the DLC3. 
6. Using a check wire, perform the zero point calibration of the yaw rate and deceleration sensor.

CAUTION:  If the ignition switch is turned ON for more than 15 seconds with the shift lever in the P position after zero point of the yaw
rate and acceleration sensor has been cleared, only the zero point of the yaw rate sensor will be stored. If the vehicle is driven under this
condition, the skid control ECU will recognize that zero point calibration of the acceleration sensor is not completed and will indicate that
there is a malfunction in the VSC system using the indicator light.

5. PERFORM ZERO POINT CALIBRATION OF YAW RATE AND DECELERATION SENSOR (When not Using Intelligent Tester)

NOTE:
-

While obtaining the zero point, do not vibrate the vehicle by tilting, moving or shaking it and keep it stationary. (Do not start the engine.)

-

Perform this on a level surface (with an inclination of less than 1 degree).

a. Procedures for Test Mode.

1. Turn the ignition switch OFF.

2. Using SST, connect terminals 12 (TS) and 4 (CG) of the DLC3. 

SST 09843-18040

3. Check that the shift lever is in the P position and apply the parking brake.

NOTE:  DTCs C1210/36 and C1336/39 will be recorded if the shift lever is not the P position.

b. Obtain the zero point of the yaw rate and deceleration sensor.

ABS/TCS - Zero Point Calibration Information|Page 6182 > < ABS/TCS - Zero Point Calibration Information|Page 6180