toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Lamps and Indicators - Cooling System > < Heater Control Valve|Testing and Inspection|Page 1888
Page 2
background image

1. CHECK WATER VALVE OPERATION 

a. Turn the ignition switch to ON. 
b. Operate temperature control switches to "MAX. COOL" and "MAX. WARM", then check water valve operation, as shown in the illustration. 
If operation is not as specified, proceed to the next step.

2. ADJUST WATER VALVE CONTROL CABLE 

a. Disconnect the control cable. 
b. Turn the ignition switch to ON. 
c. Set temperature control switches to "MAX. COOL".

d. Set the water valve lever to the "COOL" position, connect the control cable and lock the clamp. 

HINT:  Lock the clamp while lightly pushing the outer cable in the direction shown by the arrow in the illustration.

Lamps and Indicators - Cooling System > < Heater Control Valve|Testing and Inspection|Page 1888