toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Blower Unit|Page 5461 > < Blower Unit
Page 1
background image

Housing Assembly HVAC: Testing and Inspection
Front Cooling Unit

Inspection

INSPECTION

 

1. INSPECT COOLER UNIT 

a. CHECK EVAPORATOR FINS FOR BLOCKAGE 

If the fins are clogged, clean them with compressed air. 

b. CHECK FOR CRACKS AND SCRATCHES 

If necessary, repair or replace damaged parts.

2. INSPECT COOLER THERMISTOR RESISTANCE

On-Vehicle Inspection

ON-VEHICLE INSPECTION

 

1. INSPECT FOR LEAKAGE OF REFRIGERANT 

a. Remove the console box assembly. 
b. Remove the glove compartment door.
c. Remove the lower No. 2 finish panel. 
d. Remove the heater to register duct No. 4. 
e. Remove the lower LH finish panel. 
f.

Remove the lower cover.

g. Remove the blower controller. 

1. Disconnect the connector.
2. Remove the 2 screws and blower motor linear controller.

h. Using a gas leak detector, check for leakage. 

If there is leakage, check the tightening torque at the joints or check the evaporator. 

i.

Install the blower motor linear controller with the 2 screws. 

j.

Install the lower cover. 

k. Install the lower LH finish panel. 
l.

Install the lower No.2 finish panel. 

m. Install the glove compartment door.

2. INSPECT COOLER EXPANSION VALVE 

a. Set the manifold gauge set. 
b. Run the engine. 
c. Check quantity of gas with the sight glass in refrigeration cycle. 

1. Run the engine at 1,500 rpm for at least 5 minutes.
2. Then check that the high pressure reading is 1.37 to 1.57 Mpa (14 to 16 kgm/sq.cm, 199 to 228 psi)

d. Check the expansion valve. 

If the expansion valve is faulty, the low pressure reading will drop to 0 kPa (0 kgf/sq.cm, 0 psi)

HINT:  When the low pressure reading drops to 0 kPa (0 kgf/sq.cm, 0 psi), there is no difference in temperature between the IN and OUT

Blower Unit|Page 5461 > < Blower Unit