toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Front Unit|Page 5484 > < Power Transistor HVAC|Testing and Inspection
Page 1
background image

Power Transistor HVAC: Service and Repair
Front Unit

REMOVAL

1. DISCHARGE REFRIGERANT FROM REFRIGERANT SYSTEM

HINT:  At the time of the installation, refer to the following: 
-

Evacuate air from the refrigeration system. 

-

Charge the system with refrigerant and inspect for leakage of refrigerant.

Specified amount: 
Single A/C: 
750 ± 50 g (26.45 ± 1.76 oz.)

Dual A/C: 
1050 ± 50 g (37.03 ± 1.76 oz.)

2. DISCONNECT LIQUID TUBE 

a. Remove the 2 bolts and disconnect both tubes. 

Torque: 5.4 N.m (55 kgf.cm, 48 in.lbf) 

NOTE:  Cap the openings immediately to keep moisture or dirt out of the system. 

HINT:  At the time of the installation, refer to the following: Lubricate 2 new O-rings with compressor oil and install them to the tubes.

3. REMOVE COOLER RECEIVER 

a. Remove the 2 bolts and receiver 

HINT:  At the time of the installation, refer to the following:
If the receiver is replaced, add compressor oil to the compressor. 

Add 20 cc (0.71 fl.oz.)
Compressor oil: 
ND-OIL 8 or equivalent

b. Remove the 2 bolts and holder.

INSTALLATION