toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Components|Page 2384 > < Components|Page 2382
Page 1
background image

Variable Valve Timing Actuator: Service and Repair
Installation

3UR-FE ENGINE CONTROL: CAMSHAFT OIL CONTROL VALVE: INSTALLATION

INSTALLATION

1. INSTALL CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Exhaust Side of Bank 1)

(a) Install a new O-ring to the oil control valve.
(b) Apply a light coat of engine oil to the O-ring.
(c) Install the oil control valve with the bolt.

Torque: 10 Nm (102 kgf-cm, 7 ft-lbf)

(d) Connect the oil control valve connector.

2. INSTALL CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Intake Side of Bank 1)

(a) Install a new O-ring to the oil control valve.
(b) Apply a light coat of engine oil to the O-ring.
(c) Install the oil control valve with the bolt.

Torque: 10 Nm (102 kgf-cm, 7 ft-lbf)

(d) Connect the oil control valve connector.

3. INSTALL CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (for Intake Side of Bank 2)

(a) Install a new O-ring to the oil control valve.
(b) Apply a light coat of engine oil to the O-ring.
(c) Install the oil control valve with the bolt.

Torque: 10 Nm (102 kgf-cm, 7 ft-lbf)

(d) Connect the oil control valve connector.

Components|Page 2384 > < Components|Page 2382