toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3408 > < Initial Inspection and Diagnostic Overview|Page 3406
Page 64
background image

INSPECTION PROCEDURE

HINT:  Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes
resistance variation.

PROCEDURE

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

(a) Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.

CAUTION:  Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

NEXT -- Continue to next step.

2. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (DLC3 BRANCH WIRE)

(a) Disconnect the H93 No. 1 junction connector.
(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Initial Inspection and Diagnostic Overview|Page 3408 > < Initial Inspection and Diagnostic Overview|Page 3406