toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Components|Page 333 > < Components|Page 331
Page 1
background image

Engine Control Module: Service and Repair
Installation

3UR-FE ENGINE CONTROL: ECM: INSTALLATION

INSTALLATION

1. INSTALL GASKET

(a) Clean the ECM seal's surface with non-residue solvent.
(b) Attach a new gasket to the ECM.

2. INSTALL ECM

(a) Install the ECM with the 4 bolts.

Torque: 8.0 Nm (82 kgf-cm, 71 in-lbf)

NOTE:
-

Make sure that the gasket is not folded or caught on any area on the surrounding part.

-

Make sure that there is no foreign matter caught between the gasket and surrounding part.

-

Do not damage the gasket.

(b) Connect the 2 ECM connectors and push each lock lever down to lock the ECM connectors.

NOTE:
-

Make sure that the lock lever is raised 90° before connecting the ECM connectors. Failure to do this may cause the lock lever and terminals
to break.

-

Do not twist the wire harness when connecting the ECM connectors.

3. CONNECT CONNECTOR HOLDER BLOCK

(a) Connect the connector holder block with the 3 bolts.

Torque: 7.3 Nm (74 kgf-cm, 65 in-lbf)

Components|Page 333 > < Components|Page 331