toyota Workshop Repair Guides

Toyota Sienna AWD V6-33L Workshop Service and Auto Repair Manuals

A/C - Compressor Seized/Noisy|Page 1676 > < A/C - Compressor Seized/Noisy|Page 1674
Page 11
background image

42.

Install the new cooler condenser core with the 2 bolts.

Torque: 3.9 N.m (40 kgf.cm, 18 in..lbf)

43.

Connect the cable to the negative (-) battery terminal.

44.

Refill the vehicle with coolant.

NOTE:

For additional information, refer to the instructions on the TIS, 2004 model year Sienna Repair Manual: Cooling: Engine Coolant:
Replacement.

45.

Charge refrigerant HFC-134a (R-134a).

Specified Amount: 780 +/- 30 g (27.5 +/- 1.06 oz)

Equipment: Robinair R-134a Refrigerant Recovery/Recycling Machine (P/N ACR2000)

46.

Operate the A/C cycle for 10 minutes while the vehicle is idling.

Set up: Temperature - Max Cool (Front and Rear) Blower - High

47.

Remove metal debris from the filter supplement.

A.

Shut off the vehicle and evacuate the A/C system.

B.

Remove the suction hose.

C.

Remove the metal debris.

a. Blow shop air from the compressor side.

b. Blow shop air from the filter side.

D.

Confirm that all metal debris has been removed and reinstall the suction tube.

48.

Recharge the system.

49.

Warm up the engine.

50.

Check for refrigerant leakage and verify A/C performance.

51.

Check for coolant leakage.

52.

Initialize power Systems.

^

2004 model year Sienna vehicles:
To initialize power Systems, refer to TSB No. PG002-03, "Pre-Delivery Service (PDS) Information for Sienna."

A/C - Compressor Seized/Noisy|Page 1676 > < A/C - Compressor Seized/Noisy|Page 1674