Sienna AWD V6-3.5L (2GR-FE) (2007)
(b) Using a dial gauge, check for the runout of the front side of the intermediate shaft flange.
Maximum runout: 0.1 mm (0.004 inch)
NOTICE: Ensure that the dial gauge is set at right angles to the measurement surface.
(c)
Set a dial gauge outside the bolt hole on the rear side flange of the intermediate shaft, and check for runout in the horizontal direction.
Maximum runout: 0.1 mm (0.004 inch)
NOTICE: Ensure that the dial gauge is set at right angles to the measurement surface.
(d) Set a dial gauge to the circumference of the intermediate shaft flange, and check for runout in the vertical direction.
Maximum runout: 0.1 mm (0.004 inch)
NOTICE: Ensure that the dial gauge is set at right angles to the measurement surface.
HINT: If the intermediate shaft flange runout exceeds the maximum, replace the intermediate shaft.