toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Malfunction Indicator Lamp|Testing and Inspection|Page 7670 > < Malfunction Indicator Lamp|Testing and Inspection|Page 7668
Page 3
background image

Standard resistance (Check for short):

(d) Reconnect the ECM connector.
(e) Reconnect the combination meter connector.

OK -- REPLACE COMBINATION METER ASSEMBLY
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR (COMBINATION METER - ECM)

5. CHECK THAT ENGINE STARTS

(a) Turn the ignition switch to the ON position.
(b) Start the engine.

Result:

HINT:  *: The Techstream cannot communicate with the ECM.

B -- GO TO VC OUTPUT CIRCUIT
A -- Continue to next step.

6. CHECK HARNESS AND CONNECTOR (COMBINATION METER - BODY GROUND)

(a) Disconnect the E5 ECM connector.
(b) Turn the ignition switch to the ON position.
(c) Measure the voltage according to the value(s) in the table below.

Standard voltage:

(d) Reconnect the ECM connector.

OK -- REPLACE ECM
NG -- Continue to next step.

7. CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)

Malfunction Indicator Lamp|Testing and Inspection|Page 7670 > < Malfunction Indicator Lamp|Testing and Inspection|Page 7668