toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Malfunction Indicator Lamp|Testing and Inspection|Page 3115 > < Malfunction Indicator Lamp|Testing and Inspection
Page 2
background image

(e) Clear the DTCs See: Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/DTC Check / Clear.
(f) Check if the MIL goes off.

Standard:
MIL goes off.
OK -- REPAIR CIRCUITS INDICATED BY OUTPUT DTCS
NG -- Continue to next step.

3. CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)

(a) Disconnect the E5 ECM connector.
(b) Turn the ignition switch to the ON position.
(c) Check that the MIL is not illuminated.

OK:
MIL is not illuminated.

(d) Reconnect the ECM connector.

OK -- REPLACE ECM
NG -- Continue to next step.

4. CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)

(a) Disconnect the E5 ECM connector.
(b) Disconnect the C10 combination meter connector.
(c) Measure the resistance according to the value(s) in the table below.

Standard resistance (Check for open):

Malfunction Indicator Lamp|Testing and Inspection|Page 3115 > < Malfunction Indicator Lamp|Testing and Inspection