Sienna FWD V6-3.5L (2GR-FE) (2009)
Canister Purge Control Valve: Service and Repair
Installation
2GR-FE EMISSION CONTROL: PURGE VALVE: INSTALLATION
INSTALLATION
1. INSTALL PURGE VSV
(a) Install the Purge VSV with the bolt.
Torque: 10 Nm (102 kgf-cm, 7ft-lbf)
(b) Connect the 2 vacuum hoses and No. 1 vacuum switching valve connector.
2. INSTALL V-BANK COVER SUB-ASSEMBLY See: Engine, Cooling and Exhaust/Engine/Service and Repair/Removal and
Replacement/Installation
3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL