toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Radiator Cooling Fan Motor|Diagrams > < With Towing Package|Page 1848
Page 11
background image

1.  LOW SPEED OPERATION

Only when the A/C system is activated or the water temp. SW no.2 is turned ON, the A/C condenser fan motor and the radiator fan motor rotates
at low speed.

When the water temp. SW no.2 is turned ON, the current from HEATER fuse flows to the FAN NO. 3 relay (Coil side) to TERMINAL 1 of the
water temp. SW no.2 to GROUND, causing the FAN NO. 3 relay to turn ON. As a result, the current through the CDS fuse flows through the
same route as above, rotating the motors at low speed.

2.  HIGH SPEED OPERATION

Only when the water temp. SW no.1 is turned OFF, the A/C condenser fan motor and the radiator fan motor rotate at high speed.

When the water temp. SW no.1, the current from the RDI fuse flows to the FAN NO. 1 relay (Point side) to TERMINAL 2 of the radiator fan
motor to TERMINAL 1 to GROUND. At the same time, the current from the CDS fuse flows to TERMINAL 2 of the A/C condenser fan motor
to TERMINAL 1 to TERMINAL 3 of the FAN NO. 2 relay to TERMINAL 4 to GROUND.

As the current flows in parallel to the motors, the motors rotate at high speed.

Radiator Cooling Fan Motor|Diagrams > < With Towing Package|Page 1848