toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Hose/Line HVAC|Testing and Inspection|Page 6119 > < Hose/Line HVAC|Testing and Inspection|Page 6117
Page 3
background image

3. TIGHTEN JOINT OF BOLT OR NUT TO SPECIFIED TORQUE

NOTE:  Connections should not be torqued tighter than the specified torqued.

4. EVACUATE AIR FROM REFRIGERATION SYSTEM AND CHARGE WITH REFRIGERANT

Specified amount:
Single A/C: 800 ± 50 g (28.22 ± 1.76 oz.) 
Dual A/C (4 Door): 1,250 ± 50 g (44.09 ± 1.76 oz.)
Dual A/C (5 Door): 1,350 ± 50 g (47.61 ± 1.76 oz.)

5. INSPECT FOR LEAKAGE OF REFRIGERANT

Using a gas leak detector, check for leakage of refrigerant.

6. INSPECT AIR CONDITIONING OPERATION

Hose/Line HVAC|Testing and Inspection|Page 6119 > < Hose/Line HVAC|Testing and Inspection|Page 6117