3. TIGHTEN JOINT OF BOLT OR NUT TO SPECIFIED TORQUE
NOTE: Connections should not be torqued tighter than the specified torqued.
4. EVACUATE AIR FROM REFRIGERATION SYSTEM AND CHARGE WITH REFRIGERANT
Specified amount:
Single A/C: 800 ± 50 g (28.22 ± 1.76 oz.)
Dual A/C (4 Door): 1,250 ± 50 g (44.09 ± 1.76 oz.)
Dual A/C (5 Door): 1,350 ± 50 g (47.61 ± 1.76 oz.)
5. INSPECT FOR LEAKAGE OF REFRIGERANT
Using a gas leak detector, check for leakage of refrigerant.
6. INSPECT AIR CONDITIONING OPERATION