When the inclination of the retractor is over 45 °, check that the belt locks.
If operation is not as specified, replace the outer belt assy. 

b. Install the outer belt with the 4 bolts.

Torque: 
7.5 Nm (77 kgf.cm, 66 in.lbf) for bolt labeled A
42 Nm (430 kgf.cm, 31 ft.lbf) for bolt labeled B

c. Connect the pretensioner connector, as shown in the illustration.
d. Install the floor anchor cover.
e. Check if the ELR locks.

NOTE:  The check should be performed with the outer belt assy installed.

1. With the belt installed, check that the belt locks when it is pulled out quickly.

If operation is not as specified, replace the outer belt assy.

10. CONNECT BATTERY NEGATIVE TERMINAL

a. Connect the battery's negative terminal.

NOTE:  When disconnecting the negative (-) battery terminal, initialize the systems shown in the table after the terminal is reconnected. 

b. Check the SRS warning lamp.