toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Valve Clearance|Specifications|Page 1877 > < Valve Clearance|Specifications|Page 1875
Page 3
background image

Valve Clearance

EXAMPLE: (Intake)
Measured valve clearance = 0.44 mm (0.0173 inch) 
0.44 mm (0.0173 inch) - 0.24 mm (0.0094 inch) = 0.20 mm (0.0079 inch) 
(Measured - Specification = Excess clearance) 
Used shim measurement = 5.30 mm (0.2087 inch) 0.20 mm (0.0079 inch) + 5.30 mm (0.2087 inch) = 5.50 mm (0.2165 inch) 
(Excess clearance + Used shim = Ideal new shim)
Closest new shim = 5.50 mm (0.2165 inch) = Shim No."50" 

(3) Select a new lifter with a thickness as close as possible to the calculated values.

HINT:  
^ Lifters are available in 35 sizes in increments of 0.020 mm (0.0008 inch), from 5.060 mm (0.1992 inch) to 5.740 mm (0.2260 inch). 
^ Refer to valve lifter selection chart.

(i)

Valve lifter selection chart (intake).

Valve Clearance|Specifications|Page 1877 > < Valve Clearance|Specifications|Page 1875