c. Check for air leakage.

1. With the purge port and air inlet port closed, apply 19.6 kPa (0.2 kgf/sq.cm, 2.81 psi) of pressurized air into the vent port, then confirm

that pressure is retained for 1 minute. If the result is not as specified, replace the charcoal canister assembly.

d. Check the leak detection pump.

1. Remove the 3 bolts and the detection pump from the charcoal canister.
2. Check that air flows from port A to B.

NOTE:
-

Do not damage the O-ring

-

Be careful that the foreign matter does not come in the pump. If the result is not as specified, replace the charcoal canister assembly.

3. Connect the positive (+) lead of the battery to terminal 7 and the negative (-) lead to terminal 6.
4. Check that the valve is closed. If the result is not as specified, replace the charcoal canister assembly.
5. Install the detection pump with the 3 bolts.

Torque: 5.4 N.m (55 kgf.cm, 48 in.lbf)