toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Oxygen Sensor > < Malfunction Indicator Lamp|Testing and Inspection
Page 2
background image

OK -- REPLACE ECM
NG -- CHECK AND REPAIR HARNESS AND CONNECTOR

3. CHECK THAT MIL IS ILLUMINATED

(a) Check that the MIL is illuminated when turning the ignition switch to the ON position.

Standard:
MIL is illuminated.
OK -- SYSTEM OK
NG -- Continue to next step.

4. INSPECT COMBINATION METER (MIL CIRCUIT)

(a) See the combination meter troubleshooting  (See: Instrument Panel, Gauges and Warning Indicators/Testing and Inspection/Symptom

Related Diagnostic Procedures/Meter / Gauge System/Problem Symptoms Table).
NG -- REPAIR OR REPLACE BULB OR COMBINATION METER
OK -- CHECK AND REPLACE HARNESS AND CONNECTOR (COMBINATION METER - ECM)

Oxygen Sensor > < Malfunction Indicator Lamp|Testing and Inspection