Supra L6-2997cc 3.0L DOHC MFI (1998)
Reference Charts
INSPECT CONNECTING ROD ALIGNMENT
Using a feeler gauge and rod aligner, check the connecting rod alignment.
-
Check for out-of-alignment
Maximum out-of-alignment: 0.05 mm (0.0020 inch) per 100 mm (3.94 inch)
If out-of-alignment is greater than maximum, replace the connecting rod assembly.
-
Check for twist