Supra Liftback L6-2997cc 3.0L DOHC MFI Twin-Turbo (1997)
Refrigerant Pressure Sensor / Switch: Service and Repair
PRESSURE SWITCH REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
INSTALLATION HINT: Evacuate air from refrigeration system.
See: Service and Repair/Discharging & Evacuating System
Charge system with refrigerant and inspect for leakage of refrigerant.
See: Service and Repair/Charging the System
Specified amount:
700 ± 50 g (24.96 ± 1.76 oz.)
2. REMOVE PRESSURE SWITCH
a. Disconnect the connector.
b. Remove the pressure switch from the liquid tube.
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
INSTALLATION HINT: Lubricate a new O-rings with compressor oil and install the switch.
HINT: Lock the pressure switch mount on the tube with an open end wrench, being careful not to deform the tube, and remove the switch.
INSTALLATION
Installation is in the reverse order of removal.