toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

REMOVAL

1. DISCONNECT REFRIGERANT FROM REFRIGERATION SYSTEM

HINT:  At the time of installation, please refer to the following item.
Evacuate air from refrigeration system.
Charge system with refrigerant and inspect for leakage of refrigerant.
Specified amount: 700 ± 50 g (24.69 ± 1.76 oz.)

2. REMOVE PRESSURE SWITCH FROM LIQUID TUBE

Disconnect the connector and remove the pressure switch.
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)

HINT:
^

Lock the switch mounted on the tube with an open end wrench, being careful not to deform the tube and remove the switch.

^

At the time of installation, please refer to the following item.
Lubricate a new O-ring with the compressor oil and install the switch.

INSTALLATION

Installation is in the reverse order of removal.

Solar Sensor, HVAC > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection