Generator: Testing and Inspection

1. INSPECT ROTOR FOR OPEN CIRCUIT

Using an ohmmeter, check that there is continuity between the slip rings.
Standard resistance: 2.7-3.1 Ohms at 20 °C (68 °F)
If there is no continuity, replace the rotor.

2. INSPECT ROTOR FOR GROUND

Using an ohmmeter, check that there is no continuity between the slip ring and rotor.
If there is continuity, replace the rotor.

3. INSPECT SLIP RINGS

a. Check that the slip rings are not rough or scored.

If rough or scored, replace the rotor.

b. Using a vernier caliper, measure the slip ring diameter.

Standard diameter:
14.2-14.4 mm (0.559-0.567 in.)
Minimum diameter:
12.8 mm (0.504 in.)
If the diameter is less than minimum, replace the rotor.