T100 Extra Cab Pickup 4WD V6-3.4L (5VZ-FE) (1997)
Evaporator Case: Service and Repair
Removal and Installation
COOLING UNIT REMOVAL
1. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
INSTALLATION HINT: Evacuate air from refrigeration system.
See: Service and Repair
See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Leakage of Refrigerant
Charge system with refrigerant and inspect for leakage of refrigerant.
Specific amount:
850 ± 50g (29.98 ± 1.76 oz.)
2. DISCONNECT SUCTION HOSE AND LIQUID TUBE
Remove the 2 nuts and both tubes.
Torque:
Liquid tube: 14 N.m (140 kgf.cm, 10 ft.lbf)
Suction hose: 32 N.m (330 kgf.cm, 24 ft.lbf)
REMOVAL NOTE: Cap the open fitting immediately to keep moisture or dirt out of the system.
INSTALLATION HINT: Lubricate 2 new O-ring with compressor oil and install the tubes.
3. REMOVE 2 GROMMETS
4. REMOVE DRAIN PIPE GROMMET
5. REMOVE GLOVE COMPARTMENT PARTS