T100 Extra Cab Pickup 4WD V6-3.4L (5VZ-FE) (1997)
Hose/Line HVAC: Service and Repair
Refrigerant Lines
1. DISCHARGE REFRIGERANT IN REFRIGERATION SYSTEM
2. REPLACE FAULTY TUBE OR HOSE
NOTE: Cap the open fittings immediately to keep moisture or dirt out of the system.
3. TORQUE CONNECTIONS TO SPECIFIED TORQUE
NOTE: Connections should not be torque tighter than the specified torque.
Compressor x Discharge hose
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
Compressor x Suction hose
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
Condenser x Discharge tube
Torque: 10 N.m (100 kgf.cm, 7 ft.lbf)
Condenser x Liquid tube
Torque: 10 N.m (100 kgf.cm. 7 ft.lbf)
Receiver x Liquid tube
Torque: 5.4 N.m (55 kgf.cm. 48 in..lbf)
Cooling unit x Liquid tube
Torque: 14 N.m (140 kgf.cm, 10 ft.lbf)
Cooling unit x Suction tube
Torque: 33 N.m (330 kgf.cm, 24 ft.lbf)
Expansion valve x Liquid tube
Torque: 22 N.m (225 kgf.cm, 16 ft.lbf)
Expansion valve x Evaporator
Torque: 13 N.m (135 kgf.cm. 9 ft.lbf)
Liquid line (union nut)
Torque: 14 N.m (140 kgf.cm, 10 ft.lbf)