T100 Pickup 2WD L4-164.4 2693cc 2.7L DOHC (3RZ-FE) (1995)
NOTICE: Pulling on or bending the cords may damage the conductor inside.
5. DISCONNECT HIGH-TENSION CORDS FROM DISTRIBUTOR CAP.
-
Using a screwdriver, lift up the lock claw and disconnect the holder from the distributor cap.
-
Disconnect the high-tension cord at the grommet. DO NOT pull on the cord.
NOTICE:
-
Pulling on or bending the cords may damage the conductor inside.
-
Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.
6. INSPECT HIGH-TENSION CORD RESISTANCE.
-
Using an ohmmeter, measure the resistance.
Maximum resistance: 25 k Ohms per cord
-
If the resistance is greater than the maximum, check the terminals.
-
If necessary, replace the high-tension cord.
7. RECONNECT HIGH-TENSION CORDS TO DISTRIBUTOR CAP.