Intake Air Temperature Sensor: Specifications

RESISTANCE

Between Terminals THA and E2 of the Volume Air Flow Meter

At -20°C (-4°F) ...............................................................................................................................................................................................  10 - 20 k ohms
At 0°C (32°F) .....................................................................................................................................................................................................  4 - 7 k ohms
At 20°C (68°F) ...................................................................................................................................................................................................  2 - 3 k ohms
At 40°C (104°F) ...........................................................................................................................................................................................  0.9 - 1.3 k ohms
At 60°C (104°F) ...........................................................................................................................................................................................  0.4 - 0.7 k ohms