toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Igniter <--> [Ignition Control Module]|Locations|Page 3019 > < Igniter <--> [Ignition Control Module]|Locations|Page 3017
Page 1
background image

Igniter: Testing and Inspection

INSPECTION

NOTE: This is a test of the ignition circuit. As there is no component test of the Igniter itself, a process of elimination is used to find if the Igniter is at
fault.

Engine Control Module Terminal Identification

1. Using a voltmeter, back probe Engine Control Module (ECM) terminals IGT and E1.
2. Crank or start engine. To prevent flooding during testing, don't crank engine for more than 1 or 2 seconds at a time. Measure voltage.

Standard Voltage: 0.7 - 1.0 volts 

3. If no voltage reading was obtained in step 2, recheck voltage, substituting body ground for terminal E1.
4. If voltage was present in step 3, inspect wiring and connection between ECM terminal E1 and body ground. If wiring and connection were not at

fault, replace ECM.

5. If voltage was not present in step 3, inspect fusible link, Ignition Switch, wiring and connectors between battery, Ignition Coil (+), and Igniter

assembly.

6. If no faults were found in steps 1 through 5, proceed with this test. If faults were found and corrected, verify problem still exists prior to

proceeding with this test.

Igniter <--> [Ignition Control Module]|Locations|Page 3019 > < Igniter <--> [Ignition Control Module]|Locations|Page 3017