T100 Pickup 4WD V6-180.5 2959cc 3.0L SOHC (3VZ-E) (1993)
Air Flow Meter/Sensor: Specifications
RESISTANCE
Between terminals E1 and FC
Measuring plate fully closed ....................................................................................................................................................................................... infinity
Measuring plate other than closed ................................................................................................................................................................................... zero
Between terminals VC and E2
Always ........................................................................................................................................................................................................... 200 - 400 ohms
Between terminals THA and E2
At -20°C (-4°F) ............................................................................................................................................................................................... 10 - 20 k ohms
At 0°C (32°F) ..................................................................................................................................................................................................... 4 - 7 k ohms
At 20°C (68°F) ................................................................................................................................................................................................... 2 - 3 k ohms
At 40°C (104°F) ........................................................................................................................................................................................... 0.9 - 1.3 k ohms
At 60°C (104°F) ........................................................................................................................................................................................... 0.4 - 0.7 k ohms
Between terminals VS and E2
Measuring plate fully closed .......................................................................................................................................................................... 200 - 600 ohms
Measuring plate fully open ............................................................................................................................................................................ 20 - 1200 ohms
NOTE: Resistance between terminals E2 and VS will change in a wave pattern as the measuring plate slowly opens.