toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Ignition Cable|Locations|Page 2151 > < Ignition Cable|Locations
Page 1
background image

Ignition Cable: Testing and Inspection

INSPECTION

INSPECT HIGH-TENSION CORDS

(a) Remove the air cleaner cap and MAF meter assembly.

(b) Disconnect the high-tension cords from the spark plugs. Disconnect the high-tension cords at the rubber boot. DO NOT pull on the cords.

NOTICE:  Pulling on or bending the cords may damage the conductor inside.

(c) Disconnect the high-tension cords from the ignition coils.

(1) Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.

(2) Disconnect the high-tension cord at the grommet. DO NOT pull on the cord.

NOTICE:  Pulling on or bending the cords may damage the conductor inside.Do not wipe any of the oil from the grommet after the
high-tension cord is disconnected.

(d) Inspect the high-tension cord resistance.

Using an ohmmeter, measure the resistance. 

Maximum resistance: 25 k ohms per cord

If the resistance is greater than maximum, check the terminals. If necessary, replace the high-tension cord.

(e) Reconnect the high-tension cords to ignition coils.

Ignition Cable|Locations|Page 2151 > < Ignition Cable|Locations