T100 SR5 Extra Cab Pickup 4WD V6-3.4L (5VZ-FE) (1998)
Starter Motor: Service and Repair
Disassembly and Reassembly
DISASSEMBLY
1. REMOVE FIELD FRAME AND ARMATURE
a. Remove the nut, and disconnect the lead wire from the magnetic switch terminal.
Torque: 5.9 N.m (60 kgf.cm, 52 in.lbf)
b. Remove the 2 through bolts
Torque:
1.2 kW, 1.4 kW type: 5.9 N.m (60 kgf.cm, 52 in.lbf)
1.8 kW type: 9.3 N.m (95 kgf.cm, 82 in.lbf)
c. Pull out the field frame with the armature from the magnetic switch assembly.
NOTE: Align the protrusion of the field frame with cutout of the magnetic switch.
d. Remove the O-ring.
HINT: Use a new O-ring
2. REMOVE STARTER HOUSING, CLUTCH ASSEMBLY AND GEAR
a. Remove the 2 screws.