Tacoma 2WD V6-3.4L (5VZ-FE) (1995)
-
While holding port C closed, apply vacuum (980 Pa, 7.4 mmHg, 0.29 in.Hg) to port A and check that air flows into port B.
-
If a problem is found, replace the charcoal canister.
4. REINSTALL CHARCOAL CANISTER.