Positive Crankcase Ventilation Valve: Testing and Inspection

1. REMOVE PCV VALVE.

-

Disconnect the PCV hose from the PCV valve.

-

Remove the PCV valve.

2. INSTALL CLEAN HOSE TO PCV VALVE.
3. INSPECT PCV VALVE OPERATION.

-

Blow air into the cylinder head cover side, and check that air passes through easily.

CAUTION: Do not suck air through the valve. Petroleum substances inside the valve are harmful.

-

Blow air into the air intake chamber side, and check that air passes through with difficulty.

-

Blow air into the air intake chamber side when lift up the inside valve, and check that there is a strong resistance to air flow.

-

If operation is not as specified, replace the PCV valve.

4. REMOVE CLEAN HOSE FROM PCV VALVE.
5. REINSTALL PCV VALVE.